5 rs-232c cable connection, 6 mode setting, Rs-232c cable connection – Toshiba SX 2000 User Manual

Page 40: Mode setting

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

1.3 Computer link mode

1.3.5

RS-232C cable connection

Cable connection examples show as below.

• Use shielded twisted-pair cable for data communication suited to RS-232C

standard. The cable shield should be connected to single -point ground.

Master

computer

RXD

TXD

DTR

SG

DSR

RTS

CTS

Shielded twisted-pair cable

15 m max.

S2T

(RS-232C)

1

SG

2

RXD

3

TXD

4

5

SG

6

5 Vdc

7

RTS

8

CTS

9

5 Vdc

S2T, D-Sub 9-pin female connector is provided. Use D-Sub 9-pin male connector

as cable side.

RTS signal (pin 7) of the S2T is ON while power on.

CTS signal (pin 8) of the S2T has no mean on Communication control.

1.3.6

Mode setting

The operation mode of the S2T’s link port is selected by the special resister provided
on the S2T CPU module.

The operation mode is internally set at the timing of power-up. Setting changes while

power on is not effective.

To select the computer link mode, the special resister SW069 set to "0". (SW069=0)

At the factory, the computer link mode is selected.

S2T

resister

Name

Function

SW069

link port operation mode

0: computer link mode

2: Free ASCII mode

6F8C0926

23

Advertising