Transfer parameter table – Toshiba SX 2000 User Manual

Page 59

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Transfer parameter table

Chapt.1 System Configuration

Transfer object

Bank/CH

TYPE

Leading address

Transfer size

Status

flag

u.

0)

w

'u)

0)

u.

3

CL

O

XWATA/ register

0

HOO

0 to 511 (T3H/S2T)

0 to 255 (T3)

0 to 63 (T2/T2E)

1 to 256

(T3H/T3/S2T)

1 to 64

(T2/T2E/T2N)

None

W register

0

H01

0 to 2047 (T3H/T2N/S2T)

0 to 1023(T3/T2/T2E)

1 to 256

None

LW register

0

H02

0 to 255
(T3H/T3/T2/T2E/T2N/S2T)

1 to 256

None

RW register

0

H03

0 to 999 (T3H/S2T)

0 to 511 (T3)

0 to 255 (T2N)
0 to 127 (T2/T2E)

0to63(T1)

1 to 256

(T3H/T3/S2T)

1 to 128

(T2/T2E/T2N)

1 to64(T1)

None

D register

0

H04

0 to 8191

(T3H/T3/T2N/S2T)

0 to 4095 (T2/T2E)

oto 1023(T1)

1 to 256

None

F register

0

H05

0 to 32767 (T3H/S2T)

0 to 8191 (T3)
0 to 1023 (T2/T2E/T2N)

1 to 256

None

Expanded F register

(1C memory card)

1 to 15

(T3H/T3/T2)

H05

0 to 8191

1 to 256

None

1 or 2 (T3H)

H06

0 to 65535 (Bank 1)

0 to 57343 (Bank 2)

1 to 256

None

Expanded F register

(T2E/S2T

internal memory)

1 to 3 (T2E)

1 to 15(S2T)

H05

0 to 8191

1 to 256

None

1 to 8 (S2T)

H06

0 to 65535 (Bank 1 to 7)

0 to 57343 (Bank 8)

1 to 256

None

TOSLINE-S20

scan memory

1 or 2

(T3H/T3/S2T)

1 (T2/T2E)

H10

0 to 1023 (S20)

1 to 256

Yes

TOSLINE-S20LP

scan memory

1 or 2 (T3H/S2T)

1 (T2N)

H10

0 to 4095 (S20LP)

1 to 256

Yes

EEPROM (D register)

0

H20

0 to 8191 (T3H/T3/S2T)

0 to 4095 (T2/T2E/T2N)

0 to 511 (T1)

Source (read):

1 to 256

None

Destination (write):

1 to 128 (T3H/S2T)

1 to 64 (T3)

1 to 32

(T2/T2E/T2N)

1 to 16 (T1)

T2E communication

card / T2N / S2T link port

0

H30

0

1 to 256 *2

Yes

Global variable

0 to 7 (S2T)

H51

0 to 16383 (TC-net)

0 to 32767 (C2)

1 to 256

None

*1) When S20 is transfer source, the scan healthy map is created, (max. 16 words)

In case of S20LP, no status flag is added.

*2) When the link port is transfer source (receiving), the transfer size must be 256 (fixed).
*3) When the link port is transfer source (receiving), 2 words of status flag is added.

When it is destination (transmitting), 1 word of status flag is added.

*4) PU672T has the expansion memory, and use 512k words expanded file resister.

PU662T don’t have the expansion memory, so this function can’t be used.

42

Sequence Controller S2T