2 expansion interface, 3 expansion cables, Expansion interface – Toshiba SX 2000 User Manual

Page 70: Expansion cables

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

1.5 Units

1.5.2

Expansion interface

The expansion interface IF661 is mounted on the left side slot of base to expand

bases after removing the unit cover. Set the unit No. (called unit address) before
operating. The unit address is set by a rotary switch in the middle of the expansion
interface removed the cover.

Setting the unit No.

The rotary switch to set unit address is provided between two expansion connectors.
The upper side connector is for input from previous unit and the lower side connector

is for output to the next unit.

Mounted on

Switch setting

Remarks

Basic unit

0

Expansion unit

1,2,3

Set in order to 1>2>3, starting from the unit

closest to the basic unit.

NOTE

i)

Switches will be set to 0 at the factory.

ii) Be careful not to duplicate unit Nos. on units.

iii) Do not use setting 4 - 9, as these are not for use.

1.5.3

Expansion cables

These are used for connecting the basic unit and the expansion units.

They are available in the following four lengths.

Type

Length

Remarks

CS6R3

30cm

CS6R5

50cm

CS6R7

70cm

CS6*1

1.2m

NOTE

The maximum cable length between units is 1.2m.

The maximum total cable length is 3.6m.

6F8C0926

53