CIRCUTOR CIRLAMP Series User Manual

Page 16

Advertising
background image

4.5.- DATABASES

CirLAMP Manager has two databases:

4�5�1� MEASUREMENTS DATABASE

The measurements database comprises the following features:

A database for 1000 light points, with capacity to store 1 million logs.

Hardware: non-volatile memory without battery.

Non-volatile memory write policy to save maximum write cycles on FLASH memory.

Delete policy for oldest information.

Automatic node registration.

Automatic node withdrawal.

4�5�2� ALARM DATABASE

The alarm database comprises the following features:

Database for each light point with capacity for 50,000 logs.

Hardware: non-volatile memory without battery.

Non-volatile memory write policy to save maximum write cycles on FLASH memory.

Delete policy for oldest information.

4.6.- WEB SERVER

CirLAMP Manager has a configuration web site where the user can fully configure the config-

uration parameters of each light point. Furthermore, the unit has an XML server, so that it can

be integrated into any global control and maintenance platform.

4�6�1� HOME SCREEN

CirLAMP Manager is accessed via an Ethernet connection.

The default IP address of the unit is:

192�168�42�30.

It can also be accessed from a local IP on the Ethernet port:

100�0�0�1�

The web site detects the browser language. If the browser’s language is Spanish, the web site

will be shown in Spanish. Otherwise, the language will be English.

You can also select the language using the buttons that appear on the upper left part of the web

site (

Figure 8

).

16

CirLAMP system

Instruction Manual

Advertising