CIRCUTOR CIRLAMP Series User Manual

Page 96

Advertising
background image

9.4.- CirLAMP Node DALI

AC power supply

Mode

Self-powered

Rated voltage

184 ... 276 V ~

Frequency

50/60Hz

Consumption

2W 16VA

Installation category

CAT III 300 V

Voltage measurement circuit

Voltage measurement margin

184 ...276 V ~

Input impedance

600 MΩ

Installation category

CAT III 300 V

Current measurement circuit

Current measurement margin

0.1 ... 3 A

Minimum measurement current (Istart)

0.08 A

Installation category

CAT III 300 V

Measurement accuracy

Voltage measurement

< 5% of full-scale

Current measurement

< 5% of full-scale

Active and reactive power measurement

< 5% of full-scale

Relay output: Control relay ON/OFF

Maximum voltage, open contacts

250 V ~

Maximum current

10 A

Maximum switching power

2500 W (AC1)

Electrical life (at full load)

100x10

3

cycles

Mechanical life

10x10

6

cycles

Communications Protocol DALI

Output voltage

15 V

Current

12 mA

Peripheral admitted No�

1

Standard

EN-62386-101:2009, EN-62386-102:2009

PLC (Power Line Communications)

Hardware

CENELEC B DCSK

Baud rate

2400 bauds with repeater management

Protocol

CirPLC (DCSK)

Insulation

Alternating voltage

4 kV RMS 50 Hz for 1 minute

Overimpulse

1.2/50 μs 0R source impedance

2 kV UNE-EN 61000-4-5:2007 + CORR:2010