4�6�3�1�3� Scheduling time intervals in hours

If the

CirLAMP Manager has the

input and output module (

M8I8O Expansion module) the

work intervals can be programmed automatically from

Sunrise (Sunrise time).

Figure 20:Screen for scheduling time intervals in hours�

The parameters are:

Cnt: Node identifier.

inTime: Interval 1 activation time. This parameter cannot be modified; it coincides

with the

Sunrise value (Sunrise time).

power1: Power value in % during interval 1.

firstTime: Interval 2 activation time.

power2: Power value in % during interval 2.

secondTime: Interval 3 activation time.

power3: Power value in % during interval 3.

thirdTime: Interval 4 activation time.

power4: Power value in % during interval 4. Interval 4 will last until the node has

no power supply.

Click on the

Send button to send the data to the unit.

Read access user: The programming of intervals in hours cannot be modified.