The unit features:

- A configuration web server, where the user can configure all the programming param-

eters for each light point.

- PLC (Power Line Communication) with the nodes on CENELEC Band B.
- A database for 1000 nodes, with capacity to store 1 million logs.
- An astronomical clock to switch each light point on and off (compatible with expansion

module

M8I8O).

- 11 indicator LEDs.

CirLAMP Manager can be expanded with 1 expansion module:

M8I8O, expansion module with eight inputs and eight outputs.

The

CirLAMP Nodes are regulating units that are installed at each light point.

They measure the main electrical parameters (voltage, current, active power, reactive power)

independently.

There are two

CirLAMP Node models depending on the ballast:

CirLAMP Node DN, a regulating unit for lighting with electronic ballasts or bi-level

drivers.

CirLAMP Node 1 ��� 10V, a regulating unit for lighting with electronic ballasts or drivers

with a regulation range from 1 to 10V.

CirLAMP Node DALI, a regulating unit for lighting with electronic ballasts or drivers

with a DALI communications.