CIRCUTOR CIRLAMP Series User Manual

Page 40

Advertising
background image

4�6�4�7� E07-L07, Alarm adjustment

Format of file

E07 (

Figure 37

):

<Order IdReq=”E07” IdPet=”2” Version=”3�1”>

<CirLamp Id=”CIR0000001”>

<E07 ActDate=”20121114165000000W”>

<Node

nodeId=”7000007”>

<Alarms blinkActive=”31” blinkTime=”301” blinkTimes=”3” blinkTo-

talTime=”7201” brokenActive=”31” brokenTime=”3601” capacitorReactive=”51” capac-

itorTime=”3601” powerLamp=”151” timeAlarm=”3663” percentageAlarm=”33” factor-

Power=”0�93”/>

</Node>

</E07>

</CirLamp>

</Order>

Figure 37: File E07�

Format of file

L07 (

Figure 38

):

<Report IdRpt=”L07” IdPet=”148” Version=”3�1”>

<CirLamp Id=”CIR0000000001”>

<L07

Fh=”20140310155534W”>

<Node Id=”1301250033” Fh=”20140310155518W” powerLamp=”151”

timeAlarm=”3661” percentageAlarm=”31” factorPower=”0�93” brokenTime=”0” blink-

Times=”3”/>

</L07>

</CirLamp>

</Report>

Figure 38: File L07�

Where:

Root element: <Report/Order>

<Report/Order> is the root element of the file. Its attributes indicate the data necessary to

process the file:

Table 34:File E07-L07, element <Report/Order>

Attribute

Description

IdRpt/IdReq

Report/order identifier.

IdPet

Single identifier for the order.

Version

Version identifier.

Container element: <CirLamp>

< CirLamp> is the container element for the report order:

Table 35:File E07-L07, element <CirLamp>

Attribute

Description

Id

CirLamp Manager identifier.

40

CirLAMP system

Instruction Manual

Advertising