Internal Switch Settings

Open the front panel on the LWD-2400 and locate the main controller board on the back of the panel.
Further locate the DIP switch on the controller board. The 8-position switch controls the parameters
shown in the figure:

F o r D im m er num b er:

S et Sw itches T o :

1

2

4

3

1-12

1 3 -24

2 5-36

3 7-48

L ogical C hannel num b er:

Sing le D im m er system s u se this settin g

N O T E : D o no t co nfuse th e

L og ical C h an nel nu m ber
w ith th e D M X b a se a dd ress.
T he D M X b a se ad d ress fo r
each D im m er ca n b e set
in d ep en d en tly u sing the
D IM M E R su bm enu .

8

m sb lsb
R R - D im m er #4
R L - D im m er #3
L R - D im m er #2
L L - D im m er #1

C lear All
E n ab le M u ltip le W ALL D IM M E R S
E n ab le W A LL P AN E LS
V irtu al C h ann els
C u rrent Ph ase arrangem ent
“M ute” dim m er m ode (d oes n ot respond to polls, b ut fires chann els)

S W IT C H to R IG H T

SW IT C H to L E FT

N orm al

D isable W ALL PA N E LS

R eal C h an nels

Alt P hase arrangem en t

N orm al D im m er m od e (respond s to p olls)

D isab le M u ltiple W A LL D IM M E R S

D IM M E R LO G IC A L N U M B E R

lsb

m sb

1

Controller Board Configuration Switch Settings

Powering It Up For The First Time

Make sure that all 12 channel output breakers are in the off position.

There is no direct on/off switch on the LWD-2400. Input power to the unit is controlled by input breakers
located on a separate electrical sub panel. If not already on, turn ON the power input breakers.

After applying power, the LCD should illuminate and go through a quick process of “downloading scenes”.
After that, the display should be alternating between these three screens:



NEXT

DOWN

ENTER

PREV

UP

LITESCAPE (tm)
VERSION 2.1b

NEXT

DOWN

ENTER

PREV

UP

LITESCAPE (tm)
7:26:48 PM

NEXT

DOWN

ENTER

PREV

UP

LITESCAPE (tm)
THU SEP 14 2003

Power Up Menu Sequencing