QuickStart Procedures—Presets

Litescape User’s Manual, Page 17

C

HAPTER

7: P

RESETS

How to Program Presets from the LWD Control Panel

1

From

MAIN MENU press the right arrow key 5 times or until rooms blinks in the display.

2

Press

ENTER.

3

The first ROOM will blink in the display. To select a different ROOM in the system, press the up arrow
key until the room number or name is blinking in the display under

ROOM.

4

Press the right arrow key 2 times, passing by the

ZONE display, so that the first preset is blinking in

the display underneath the word

PRESET.

5

Use the up and down arrow keys to select the preset to be programmed. Press

ENTER to select that

preset.

6

Press the right arrow key 7 times or until

PRESET PROGRAM MODE is displayed. Use the up or

down arrow key to select

edit mode.

7

Press the right arrow key once to set the level for each ZONE. A level for each of 12 possible ZONES
can be assigned to the current PRESET. Use the right and left arrow keys to move from ZONE to
ZONE. Use the up and down arrow keys to modify the level for each ZONE.

8

To program the next preset for the room, press the left arrow key until

ROOM and PRESET are

displayed, and the

entire name of the preset previously edited is blinking. Use the up or down arrow

to select another preset.

9

When the preset to be edited next is displayed, press

ENTER. Continue as in steps 6-8 above.

How to Program a Preset Using a Fader Panel

1

Adjust the lights to the desired levels using faders on the wall panel.

2

Press and hold down the PRESET button on the wall panel that is to be programmed.

3

The preset LED will begin to blink. Continue holding the button down for 8 seconds. If it is released
prematurely, no reprogramming will occur.

How to Temporarily Disable a Wall Panel

Wall panels can be disabled temporarily by turning the key in the KEYSWITCH panel to LOCK, or with
the LWD-2400 menu as outlined below. The 3-pin priority jumper on the back of the wall panel MUST be
set to LOW PRIORITY (shorting plug over lower two pins) before it can be disabled.

1

From the

MAIN MENU, press the right arrow key 4 times or until system is blinking in the display.

Press

ENTER.

2

Press the right arrow approximately 14 times or until

LOW PRIORITY PNL is in the display.

3

The number next to

ROOM will be blinking. Use the up or down arrow to change to the room number

for the panel to be disabled.

4

Press the right arrow key once. The first two letters of the word

enabled will be blinking (or the first

three letters of

disabled if the panel is already disabled). Use the up or down arrow to change to the

state desired.

5

Press

ENTER to save the change. Press the left arrow key repeatedly to return to the MAIN MENU.