6. V-Link

3-21

Ser

ial Comm

uni
c

a

ti

ons

6.

V-Link

V-Link

• “V-Link” is the network where the computer reads from and writes to the internal

memory of the V7 series, memory card, PLC memory or temperature control/PLC2
memory using a dedicated protocol.

• Use the MJ port of the V7 series for connection with a general-purpose computer. For

connection with the PLC using a temperature controller or the PLC2Way function, use
the other MJ port and use CN1 for communications with the PLC. Data of the PLC or
temperature controller can be collected through communications with the V7 series.
Data collection is available even between the products of different manufacturers.

• Either signal level RS-232C or RS-485 can be selected. With RS-232C, one V7 series

can be connected; with RS-485, a maximum of 31 V7 series can be connected.