Read – Hakko MONITOUCH V7 series User Manual

Page 180

Advertising
background image

4

1. Ethernet

4-29

Netw

or

k C

o

mm

uni
ca
tio
n

s

Read

Read Words from PLC Memory

int HKEtn_ReadPlcMemory(WORD *dp,unsigned short Wordcnt,int
DeviceType,DWORD addr,char *lpAddr, int DFlag=1)

This function is retained until PLC data is transferred from the V7 series.

• Parameters

*dp

Target pointer of the data to be read

Wordcnt

Word count to be read (max. 2000 words)

DeviceType

Address of the device to be read (Refer to “Chapter 5 Connection to
PLCs.
”)

addr

Top memory address to be read
For YOKOGAWA or YASKAWA PLCs, specify a number “

−1” for the

address (addr).
Example: D400

→ 399 D25 → 24

*lpAddr

IP address shown as a string of characters separated by dots
Example: “192.168.XXX.XXX”

DFlag

0, 1, 2 (Refer to the table below.)

• Return values

Success

TRUE

Failure

FALSE

Error details

Get using HKEtn_GetLastError ().

• Priority and communication procedure depending on the DFlag setting are shown

below.

Contents

Word Count

No. 1

1

No. 2

1

No. n

1

DFlag

Priority

Communication Procedure

0

Communications

1

Display

2

Display

PC

Read/write request

V7

PLC

Memory card

Response

Acknowledge of completion

Response

PC

Read/write request

V7

PLC

Memory card

Acknowledge of completion