Adr - low - hi – Hakko MONITOUCH V7 series User Manual

Page 155

Advertising
background image

4-4

1. Ethernet

Nomenclature and Functions of Ethernet I/F Unit CU-03

1. LED

Indicates the status of the communication.

2. Port number setting switches

Set the port number of V7 specified on the network table using the following rotary
switches.
Example: To set port No. 1:

3. Fuse

This is the fuse for 12 VDC power supply. (Rating 2A)

4. 10BASE-T connector

This connector is used for 10BASE-T connection. (Compliant with IEEE802.3)

5. AUI connector

This connector is used for connecting the transceiver cable in the case of 10BASE2 or
10BASE5.

6. 12 VDC power supply terminal

The power source is required for the transceiver of AUI connection. Be sure to take
account of a voltage drop at CU-03 (max. 0.7 V).

* It is not necessary to use 10BASE-T.

Name

Contents

On

Off

RX

Data receive status

Currently receiving

Not receiving

TX

Data send status

Currently sending

Not sending

LNK

Link status (for 10BASE-T only)

Normal

Error

Cl

Collision

Data collision

Normal

AUI

+12V

10B-T RX TX LNK CI

ADR - LOW - HI FUSE 0V

1

2

3

4

5

6

0 1

2

3

4
5

6

7

8

9

A

B

C

D

E

F

0 1

2

3

4
5

6

7

8

9

A

B

C

D

E

F

ADR - LOW - HI

* Make sure that each I/F unit on the network

has a unique port number.

Advertising