10. DIP Switch Setting

10. DIP Switch Setting

DIP Switch (DIPSW) Setting

Set the terminating resistance for RS-422/485 connection with the DIP switch. When
setting the DIP switch, turn the power off.

- For V708/V708i:

- For V710/V710i/V712/V712i:

* Set DIPSW2 to 5 (not used) to the OFF position.

Terminating Resistance Setting (DIPSW6, 7, 8)

• When connecting the PLC at CN1 via RS-422/485 interface, set DIPSW7 to the ON

position.

• For the following connections at modular jack 1 (2), set DIPSW 6 (DIPSW8) to the ON

position.

- Master station for multi-link 2 connection
- Temperature controller network/PLC2Way connection via RS-485
- Connection with the card recorder CREC (optional)
- Connection with the serial extension I/O V-I/O (optional)
- Connection to the V7 unit at the termination of V-link connection via RS-485

100-240VAC

L N

LAN

CN1

MJ1

MJ2

PRINTER

CF

CN5

MEMORY

CN6

Side View

Rear View

DIP switch

ON

1

2

3

4

5

6

7

8

CF auto load

MJ2 (modular jack 2) terminating resistance

CN1 RD terminating resistance at pins 24 and 25

MJ1 (modular jack 1) terminating resistance

Not used