3-46

7. PLC2Way

User Log Read for YOKOGAWA’s PLC

The user log set with YOKOGAWA’s PLC “FA-M3/FA-M3R” connected at the MJ port can
be read using the macro command TEMP_CTL.

Macro

[TEMP_CTL]

This macro command controls the operation set in the memory addresses starting from
the one specified for F0 for the number of words specified for F1.

Usable Devices

TEMP_CTL: Temperature controller/PLC2Way control function

TEMP_CTL F0 F1

Return data: Data stored from PLC2Way

→ V7 series

*1 Set “0” for CPU No. 1.
*2 The registration number is stored in special register Z105.
*3 If there is no user log in the “n + 2” memory or there is an error in communications, [

−1] is stored.

PLC Memory

Internal Memory

Constant (Words)

Memory Card

Indirect

Designation

F0

F1

F0 (= $u n)

F1

n

n + 1

n + 2

n + 3

n + 4

n + 5

n + 6

n + 7

n + 8

n + 9

n + 10

n + 11

Words

User log

registration

number read

Port

number

CPU No.

−1

*1

(0 - 3)

Command

−1

Registration

number

*2

3

Latest user

log read

Port

number

CPU No.

−1

*1

(0 - 3)

Command

0

Header

0: Normal

−1: Error

*3

Year

Month

Day

Hour

Minute Second

Main
code

Sub

code

3

(ASCII)

(DEC)

“n”th user log

read

Port

number

CPU No.

−1

*1

(0 - 3)

Command

1 to 63

Header

0: Normal

−1: Error

*3

Year

Month

Day

Hour

Minute Second

Main
code

Sub

code

3

(ASCII)

(DEC)

Advertising