16. SHINKO PLC

16. SHINKO PLC

Available PLCs

Communication Setting

The recommended communication parameter settings of the PLC and the V7 series is as follows:

Available Memory

The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.

Only D register of SELMART is available. No other devices can be used.
Be sure to note the above though the setting on the V-SFT editor is possible.

Select PLC Type

PLC

Unit/Port

Connection

SELMART

SELMART-100 and later

Version O1M2-UCI-6

RS-232C [Wiring Diagram 1]

Item

Setting on PLC

V7 Comm. Parameter Setting

Baud rate

19200 bps

19200 bps

Parity

Even

Even

Transmission code

Data length

7 (ASCII)

7

Stop bit

1

1

Sumcheck

Provided (fixed)

Memory

TYPE

Remarks

D

(data register)

0