Samsung plc, Available plcs, Communication setting – Hakko MONITOUCH V7 series User Manual

Page 307: Available memory, Samsung plc -100, Available plcs -100, Communication setting -100, Available memory -100, Available plcs communication setting

Advertising
background image

5-100

17. SAMSUNG PLC

17. SAMSUNG PLC

Available PLCs

Communication Setting

The recommended communication parameter settings of the PLC and the V7 series is as follows:

Available Memory

The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.

Select PLC Type

PLC

Connection

SPC series

SPC series

RS-232C

[Wiring Diagram 1]

RS-422/485

[Wiring Diagram 2]

Item

Setting on PLC

V7 Comm. Parameter Setting

Baud rate

9600 bps

9600 bps

Parity

Not provided

Not provided

Stop bit

1

1

Terminating resistance

ON for RS-485

Memory

TYPE

Remarks

R

(input/output)

0

L

(link relay)

1

M

(internal relay)

2

K

(keep relay)

3

F

(special relay)

4

W

(data register)

5

Advertising