background image

5

19. LG PLC

5-109

Co
nne

c

tio

n

to P

L

Cs

MASTER-KxxxS

MASTER-KxxxS CNET / GLOFA CNET

Available Memory

The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.

MASTER-K10/60/200

Item

Setting on PLC

V7 Comm. Parameter Setting

Baud rate

38400 bps

38400 bps

Parity

None (fixed)

Transmission code

Data length

8 (fixed)

Stop bit

1 (fixed)

Item

Setting on PLC

V7 Comm. Parameter Setting

Baud rate

38400 bps

38400 bps

Parity

Not provided

Not provided

Transmission code

Data length

8

8

Stop bit

1

1

Memory

TYPE

Remarks

D

(data register)

0

M

(auxiliary relay)

1

P

(input/output relay)

2

Input: Read only

K

(keep relay)

3

TC

(timer/current value)

4

CC

(counter/current value)

5

TS

(timer/set value)

6

CS

(counter/set value)

7