Oxymitter 4000

A-20

Instruction Manual

IM-106-340, Rev. 4.0

May 2006

IARC has recently reviewed the animal, human, and other relevant
experimental data on silica in order to critically evaluate and classify the
cancer causing potential. Based on its review, IARC classified
crystalline silica as a group 2A carcinogen (probable human
carcinogen).

The OSHA permissible exposure limit (PEL for cristobalite is 0.05
mg/m3 (respirable dust). The ACGIH threshold limit value (TLV) for
cristobalite is 0.05 mg/m3 (respirable dust) (ACGIH 1991-92). Use
NIOSH or MSHA approved equipment when airborne exposure limits
may be exceeded. The minimum respiratory protection recommended
for given airborne fiber or cristobalite concentrations are:

CONCENTRATION

If airborne fiber or cristobalite concentrations are not known, as
minimum protection, use NIOSH/MSHA approved half face, air purifying
respirator with HEPA filter cartridges.

Insulation surface should be lightly sprayed with water before removal to
suppress airborne dust. As water evaporates during removal, additional
water should be sprayed on surfaces as needed. Only enough water
should be sprayed to suppress dust so that water does not run onto the
floor of the work area. To aid the wetting process, a surfactant can be
used.

After RCF removal is completed, dust suppressing cleaning methods,
such as wet sweeping or vacuuming, should be used to clean the work
area. If dry vacuuming is used, the vacuum must be equipped with
HEPA filter. Air blowing or dry sweeping should not be used. Dust
suppressing components can be used to clean up light dust.

Product packaging may contain product residue. Do not reuse except to
reship or return Ceramic Fiber products to the factory.

Concentration

Personal Protective Equipment

0-1 fiber/cc or 0-0.05 mg/m

3

cristobalite (the OSHA PEL)

Optional disposable dust respirator (e.g. 3M
9970 or equivalent).

Up to 5 fibers/cc or up to 10 times
the OSHA PEL for cristobalite

Half face, air purifying respirator equipped
with high efficiency particulate air
(HEPA)filter cartridges (e.g. 3M 6000 series
with 2040 filter or equivalent).

Up to 25 fibers/cc or 50 times the
OSHA PEL for cristobalite (2.5
mg/m

3

)

Full face, air purifying respirator with high
efficiency particulate air (HEPA) filter
cartridges (e.g. 3M 7800S with 7255 filters
or equivalent) or powered air purifying
respirator (PARR) equipped with HEPA filter
cartridges (e.g. 3M W3265S with W3267
filters or equivalent).

Greater than 25 fibers/cc or 50
times the OSHA PEL for
cristobalite (2.5 mg/m

3

)

Full face, positive pressure supplied air
respirator (e.g. 3M 7800S with W9435 hose
& W3196 low pressure regulator kit
connected to clean air supply or equivalent).

Advertising