Figure 2-5, Oxymitter 4000, Instruction manual – Emerson Process Management OXYMITTER 4000 IM-106-340 User Manual

Page 45

Advertising
background image

Instruction Manual

IM-106-340, Rev. 4.0
May 2006

2-7

Oxymitter 4000

Figure 2-5. Oxymitter 4000

Adapter Plate Installation

35830005

0.50 13

(

)

3.75 95

(

)

Minimum Dia
hole in wall

Stack or duct
metal wall

Mounting holes
shown rotated 45

o

Weld or bolt mounting plate to metal wall
of stack or duct; Joint must be air tight.

0.50 13

(

)

4.50 114

(

)

O.D. Ref

Pipe 4.00 in. Sched 40 Pipe
Sleeve (Not by
Rosemount Analytical)
length by Customer

Masonry
stack wall

Outside wall

surface

Joint must

be air tight

Mounting Holes

shown rotated 45

of true position

o

Field weld pipe

to adapter plate

Bolt mounting plate to

outside wall surface

2.50 (63,5)

Minimum Dia
hole in wall

Stack or duct
metal wall

Weld or bolt adapter plate to
metal wall of stack or duct.
Joint must be air tight.

Field weld pipe
to adapter plate

3.5 (89)
O.D. Ref

Pipe 3.00 in. Sched 40 Pipe
Sleeve (Not by
Rosemount Analytical)
length by Customer

Masonry
stack wall

Outside wall

surface

Joint must

be air tight

Bolt adapter plate to

outside wall surface

INSTALLATION FOR MASONRY

WALL STACK CONSTRUCTION

INSTALLATION FOR METAL WALL

STACK OR DUCT CONSTRUCTION

Notes: 1.

Dimensions are in

with

in parentheses.

inches

millimeters

out of true position

out

2.

All masonry stack work and joints except adaptor

plate are not furnished by Rosemont Analytical.