Grass Valley Kaleido-X v.7.80 User Manual

Page 476

Advertising
background image

468

Administration and Servicing

Dashboard Messages

Status dashboard messages

Notes

• There are no dashboard messages for the Kaleido-IP.

• Messages in the upgrade dashboard (see

Upgrade dashboard messages

on

page 470) apply to the Kaleido-X only.

Message

Description

7RU 4RU X16

KMV KMX

PSU A absent

PSU A is absent, overheating, has a DC
circuitry fault condition, or no current is
drawn from it.

x

PSU B absent

PSU B is absent, overheating, has a DC
circuitry fault condition, or no current is
drawn from it.

x

PSU A 48 V

PSU A is absent, overheating, has a DC
circuitry fault condition, or no current is
drawn from it.

x

PSU B 48 V

PSU B is absent, overheating, has a DC
circuitry fault condition, or no current is
drawn from it.

x

PSU A 48 V Fuse

PSU A fuse is broken.

x

x

PSU B 48 V Fuse

PSU B fuse is broken.

x

x

PSU A 12 V

PSU A is absent, overheating, has a DC
circuitry fault condition, or no current is
drawn from it.

x

PSU B 12 V

PSU B is absent, overheating, has a DC
circuitry fault condition, or no current is
drawn from it.

x

PSU A AC

PSU A power cord is unplugged.

x

PSU B AC

PSU B power cord is unplugged.

x

Duplicate IP Address
Detected

Another equipment on the network
shares the same IP address as an output
card.

x

x

x

x

x

Duplicate frame IP address

Another equipment on the network
shares the same IP address as the
multiviewer system (in a multiple output
card setup).

x

Ethernet Link Down

The output card to which this display
monitor is connected has lost its network
connection.

x

x

x

x

x

Fan 1 (replace whole
module if in error)

Fan 1 is running too low or is broken.

x

Fan 2 (replace whole
module if in error)

Fan 2 is running too low or is broken.

x

Advertising