Problems with timecode – Grass Valley PVS Series System Guide v.4.0 Dec 10 200 User Manual

Page 235

Advertising
background image

Problems with timecode

July 27, 2001

Profile XP System Guide

235

LTC:
No time code or incorrect time
code.

The incorrect LTC input is
assigned to the channel you’re
using.

Determine the LTC input
assigned to the channel by
referring to“Recording or
generating LTC” on page 187,

then modify if needed.

LTC:
No time code or incorrect time
code.

The LTC output you’re
monitoring is not assigned to the
channel.

Determine the LTC output
assigned to the channel by
referring to“Recording or
generating LTC” on page 187,

then verify cable connections.

Timecode Burn-in
Video Monitor timecode burn-in
doesn’t change.

The Video Monitor output is not
selected as the timecode output
for the channel.

Make sure the video monitor
you are connected to is selected
as a timecode output for the
channel. Refer to “Select a
timecode source for timecode
burn-in” on page 188.

Problem

Possible Cause(s)

Corrective Action

Advertising