Storage system problems, Storage system problem, Chapter 10 solving common setup problems – Grass Valley PVS Series System Guide v.4.0 Dec 10 200 User Manual

Page 236

Advertising
background image

Chapter 10

Solving Common Setup Problems

236

Profile XP System Guide

July 27, 2001

Storage system problems

This troubleshooting aid provides corrective action for some common storage system
problems. Search the table for the problem you are experiencing, then try the
corrective action. Some problems have more than one corrective action.

Problem

Possible Cause(s)

Corrective Action

No file system found message
displayed at first time power-up
of the Profile XP system.

No video file system.

If this is a first time start-up for
the system, you must create a
video file system. Create a video
file system on the storage disks.
Refer to Chapter 3, “Working
with Profile XP storage
systems”
.

No file system found message
after a video file system has
been created in the past.

All PFC500s or PFC500E
systems are not powered on and
initialized before the Profile XP
system is powered on.

PFC500 and/or one of the
expansion chassis is not
powered on and fully initialized.
Refer to “Connecting storage:
Using a single PFC500” on
page 61 o
r “Connecting storage:
Using multiple PFC500s” on
page 64.
If this does not help,
you may have a hardware
problem. Refer to the

Profile

XP Service Manual

and

PFC500 Instruction Manual. Do
not create a new file system until
you have identified the problem.
Making a new file system
destroys all existing media.

Cannot “see” the disk system in
disk utility.

Interface problem.

Check all cabling and that all
systems are fully initialized.
Refer to the

Profile XP

Service Manual

, and the

PFC500 Instruction Manual.

Advertising