Appendix A

Electrical and Environmental Specifications

254

Profile XP System Guide

July 27, 2001

Reference Genlock

LTC Timecode

GPI I/O

Characteristics

Description

Color Field Detection, Based on
SCH Phase

Requirement:

Correct color framing for signals having an
average SCH phase

±

40

°

; Lockup

±

10

°

Supplemental Data:

Once locked to color field, it will stay locked
over a range of 0

°

to

±

90

°

Burst Frequency Lock Range

Requirement:

PAL,

±

10 Hz at subcarrier

NTSC,

±

20 Hz at subcarrier

Signal Amplitude Lock Range

Requirement:

Stays locked to +6 dB and -3 dB

Reference Genlock Input Return
Loss

Requirement:

40 dB to 5 MHz

Characteristics

Description

Input

Supplemental Data:

Longitudinal Time Code. AC coupled,
differential input

Input Impedance

Supplemental Data:

20 k

.

Input Amplitude

Supplemental Data:

0.1 V p-p, differential, minimum

Maximum Input Voltage

Supplemental Data:

2.5 V p-p, differential, maximum

Characteristics

Description

GPI Input

Supplemental Data:

Inputs set to TTL level high.
Compatible with 5 volts CMOS/TTL open
collector or contact closures.

GPI Output

Supplemental Data:

Outputs are open drain drivers.
Max. voltage when outputs are open = 30V
Max. current when outputs are
closed = 200ma.

Advertising