Determining which disk modules make up a lun – Grass Valley PVS Series System Guide v.4.0 Dec 10 200 User Manual

Page 85

Advertising
background image

Determining which disk modules make up a LUN

July 27, 2001

Profile XP System Guide

85

Determining which disk modules make up a LUN

Use the Identify button in the Disk Utility to determine which disk modules in the disk
array make up a LUN. Clicking the Identify button flashes the disk LEDs of all the
drives in the LUN. This is helpful in Profile XP systems with several Fibre Channel
RAID chassis connected, for instance in locating the drives bound as hot spares.

To determine LUN physical location:

1. Start Configuration Manager using the desktop shortcut or by selecting

Start |

Programs | Profile Apps | Configuration Manager

. The Configuration Manager

dialog box appears.

2. Click

File System

in the Configuration Manager window. Page 1 of the Disk Utility

dialog box appears.

3. Select a LUN in the LUN setup list.

4. Click

Identify

. The dialog box appears.

5. Locate the LUN physical location, then click

OK

to clear Identify mode.

6. Click

Cancel

to close the Disk Utility dialog box.

Advertising
This manual is related to the following products: