Starting the Profile XP system
When starting your system, you must power-on the Profile XP Media Platform and
the PFC500 storage system as described in the following procedure.
To power-on the Profile XP system:
1. Turn on power to all peripheral devices connected to the Profile XP. The PFC500
and PFC 500E power switches are located behind the fan pack as shown.
2. After about 90 seconds, verify that the
System Check LED
is out on the PFC 500
Fibre Channel RAID Chassis and all PFC 500E Expansion Chassis, if installed.
Refer to the PFC 500 Instruction Manual for more information if the System Check
LED remains lit.
NOTE: Do not power-on the PVS1000 until the PFC500 Fibre Channel RAID
storage system is fully initialized; approximately 2-3 minutes.
3. Turn on the power to the Profile XP Media Platform and wait for Windows NT to
initialize and perform auto-logon. The Windows NT desktop will appear after
successful auto-logon.