3 me-rtr router’s bmk menu maps – Magnum Energy ME-RTR Router User Manual

Page 117

Advertising
background image

Page 109

©

2014 Magnum Energy, Inc.

Using a BMK: Operation/Monitoring

Figure 8-4, BMK SETUP Menu Maps

METER: 05I Days Since 100%
This read-only menu displays the number of days since the battery was at 100% SOC, and is

calculated in the router.

Info: This display resets either once the battery SOC reaches 100%, power to the

router is lost, or the data communications from the BMK is lost.

Info: The METER: 05I Days Since 100% menu uses information from the METER:05A

BMK SOC menu to determine the last time the battery SOC was at 100%.

Info: For the METER: 05I Days Since 100% to increment, the optional battery monitor

(ME-BMK or ME-BMK-NS) must be connected and the METER: 05A BMK SOC meter must

not display 100% [must display a valid SOC value – Think’n, No Comm, or any BMK fault

(i.e., Factory Fault, Power-up Fault, or Unknown Fault ##) are not valid SOC values].
Info: The METER: 05I Days Since 100% menu is similar to the 04F Since 100% Days

menu (calculated in AGS). If an AGS is installed at a later date (or router is reconnected),

the two menus are not coordinated with each other. However, they will be automatically

synchronized once the BMK’s METER: 05A BMK SOC menu reaches 100% SOC (or you

can manually synchronize by momentarily removing the network cable from the BMK).

8.2.3

ME-RTR Router’s BMK Menu Maps

Figures 8-4, 8-5 & 8-6 are a complete overview of the battery monitor settings and information

displays available from the ME-RTR router’s SETUP and METER menus. Refer to Appendix A in the

back of this manual for a glossary of abbreviations that may appear on the router’s LCD display.

METER: 05G Minimum VDC
This menu displays the lowest battery voltage since the last reset. The voltage shown on the display

is averaged each second, and is helpful when troubleshooting or detecting an over-discharge

condition. To reset this display, press and hold the rotary SELECT knob for ~2 seconds while the

Minimum VDC display is shown. If the battery monitor is not connected or not communicating,

the display will show “0.0”.
METER: 05H Maximum VDC
This menu displays the highest battery voltage since the last reset. The voltage shown is averaged

each second, and this allows you to check your charging system (e.g., battery charger, charge

controller, etc.,) to ensure the charging voltage has been attained. This is also helpful when

troubleshooting or detecting if an overcharge condition has occurred. To reset this display, press

and hold the rotary SELECT knob for ~2 seconds while the Maximum VDC display is shown. If the

battery monitor is not connected or not communicating, the display shows “0.0”.

05A Charge
Efficiency = Auto

P# View BMK SETUP

BMK Home screen

P

Set Charge
Efficiency = Auto

P# edit BMK SETUP

R

Auto, 50-99%

System Home screen

Battery Monitor
SOC: 100% -103AHrs
27.2VDC 101.4ADC
P# BMK Home

Inverting
SOC: 100% Gen Off
27.2VDC 101.4ADC
ALL System Home

OR

04 AGS Setup
05 BMK Setup
06 RC Setup
ALL Select SETUP

Set Battery AmpHrs
Size = 400 AHrs

P# edit BMK SETUP

05B Battery AmpHrs
Size = 400 AHrs

P# View BMK SETUP

P

200–2500 AH

SETUP

Press

P

R

Advertising