0 attaching a remote control – Magnum Energy ME-RTR Router User Manual

Page 121

Advertising
background image

Page 113

©

2014 Magnum Energy, Inc.

Attaching a Remote

SETUP: 06 RC Setup
No setup features are allowed from the remote control; all setup must be done using the router.

The remote control can be plugged into any port (P1-P6), and can monitor any port to which an

inverter is connected. However, it must first be assigned to that port in order to monitor it. See

Figure 9-1 for help in accessing the RC Setup menu.

Default: System (appears as the assigned port for the remote control and means the remote

control will monitor the System Home port.
Range: System, Port 1 – Port 6 (shows any port activity connected to an inverter—means the

remote will monitor the specific inverter on the designated port).

Note: It is recommended that the ME-RC or ME-ARC is set to monitor “System” in most installations.
To assign a different port, press the SELECT knob and rotate to the desired port (P1-P6). Press
the SELECT knob to save the port selection.

9.0 Attaching a Remote Control

A remote control (ME-ARC or ME-RC) can be connected to the router and used in a different

location to assist with monitoring your system. Only one remote control can be used, and it must

be connected directly to one of the router ports and programmed (per SETUP: 06 RC Setup menu)

to indicate which port it is monitoring.

Info: When using a remote control, it cannot be connected to the inverter’s Network

or Remote port, it must be connected to a communications port (P1-P6) on the router.

When used in conjunction with a router, a ME-RC or ME-ARC has limited functions. The remote

control, when connected to the router, acts only as a remote monitor. It monitors the port it is set

up to display, turns all parallel inverter/chargers on/off, and displays METER and TECH information.
If the remote control that is connected is a ME-ARC, it can be used in a remote location as a remote

on/off switch, and can assist in controlling a generator that is connected to an AGS-N module

using the FAVS button. The ME-ARC does not control the inverter/chargers via the CTRL button,

nor can the SETUP button be used—all SETUP and CTRL features or functions must be done using

the CTRL and SETUP button on the router.

Info: When the ME-ARC is connected to the router, the FAVS menu can provide access

to menus that are normally locked out. The Gen Control menu—when used under the

FAVS menu— is the only one that is tested and guaranteed to work. The menus that are

under the CTRL and SETUP buttons are normally locked out, but may have been saved

in the FAVS menu. These non-tested menus may confl ict with the router settings and

should not be used to set up or confi gure the router.

Figure 9-1, Accessing the RC Setup Menu

Remote Control
MS4024PAE on Port 5
[Inv Status/Fault]
P5 RC Home

PORT

Press PORT button until RC Home screen displays

(with port# to which RC is connected).

RC Home screen

System Home screen

OR

R

P

SETUP

06A Remote Control
System

P# View RC SETUP

P

Set Remote Control
System

P# edit RC SETUP

System, Port 1-6

Inverting
SOC: 100% Gen Off
27.2VDC -101.4ADC
ALL System Home

04 AGS Setup
05 BMK Setup
06 RC Setup
ALL Select SETUP

Advertising