Page 20

Setup

MSH models only:
• 02H Input Volts AC1:
This menu displays the RMS value of the AC voltage at the inverter’s

AC1 and NEUTRAL input terminals.

MSH-RE models only:
• 02I Input Volts AC2:
This menu displays the RMS value of the AC voltage at the inverter’s

AC2 and NEUTRAL input terminals.

Info: The 02I Input Volts AC2 menu only displays if the router is connected to a dual

source inverter/charger that has an AC1 and AC2 input, such as the MSH4024RE.

Info: If the 02I Input Volts AC2 menu displays voltage (~ 50v), but the generator is off

or nothing is connected to the AC2 input, the AC2 neutral-to-ground bond connection is

not correct or not connected.

METER: 03 Timers
• 03A

Charge

Time: This meter displays the total time the charger is holding the batteries

at a high voltage level, defi ned as 0.2 volts greater than the fl oat voltage setting. The timer

counts while in Bulk, Absorption, or Equalization charge stages (or in the Constant Current and

Constant Voltage charge stages if CC/CV is selected under the SETUP/03C Battery Type menu).

The meter does not accumulate time when in Float, Charger Standby, Full, or Silent mode. The

charge timer resets whenever the charge status goes to “Charging” (AC is connected to the

inverter/charger), or the charger initiates another Bulk, EQ, or Constant Current charge cycle.

Info: The 03A Charge Time value that is displayed is used by the Max Charge Time

safety feature to determine when to display “Max Charge Time” and to blink the CHG

LED indicator.
Info: The Max Charge Time safety feature is set and enabled based on the battery type

that is selected under the SETUP/03C Battery Type menu:
a) If the battery type is ‘CC/CV’ – the Set Max CC/CV Charge Time setting is available

to set after the CV Chg Done Time (or Amps) is selected under the SETUP/03C Battery

Type: CC/CV menu.
b) If the battery type is not ‘CC/CV’ – the SETUP/03E Max Charge: Time menu is

available to set the maximum charge time.

• 03B Days Since:

◊ Absorb/CV Done – This menu displays the number of days since the Absorption charge

mode was completed (i.e., Absorb Done – Time, Amps, or SOC). This menu resets to zero once

an Absorb Done is completed as per the SETUP: 03D Absorb Done setting.

Info: The 03B Days Since: Absorb/CV Done timer resets to zero once an Absorb Done

is completed as per the SETUP: 03D Absorb Done setting; or, the Absorption Charge

mode is fi nished prematurely by starting another charge mode—such as enabling a

Start Float charge (using CTRL: 02 Charger Control/Start Float).

◊ EQ Chg Started – This menu displays the number of days since the EQ charge mode has

been enabled. This menu resets to zero once equalization has started. The SETUP: 03G Set

Days to remind when to EQ menu uses the time shown in this menu to determine when to

indicate it is time to perform an equalization charge to the batteries.

METER: 04 AGS Meters
Refer to Section 7.0

for information on all AGS menus available from the ME-RTR’s METER button.

METER: 05 BMK Meters
Refer to Section 8.0

for information on all BMK menus available from the ME-RTR’s METER button.

Advertising