Appendix B – Compatibility Matrix

Appendix B – Router Feature to Inverter Compatibility

When the ME-RTR is released with new software, some of the features and functionality in the

router may not be available in an inverter or networked accessory that has an earlier software

level. In this case, the advanced setting is not recognized and will not function. Table B-1 lists the

ME-RTR features/settings and what inverter compatibility level is required (see the “Model/Level

Required” column).
1. Go to:

http://magnumenergy.com/inverter-compatibility/

to determine your inverter’s

compatibility level (L1, L2, L3, or L4).

2. Find the features/settings you want to use in Table B-1.
3. If your inverter compatibility level is ≥ the level required, your inverter supports the setting/feature.
4. If your inverter does not have the required compatibility level for a feature/setting you want,

contact Magnum Energy for a software upgrade.

Table B-1, ME-RTR (Version 3.1) Compatibility Matrix

Button

FEATURES/SETTINGS

Model/

Level

Required

Default

Setting

Main Menu

Menu

Heading/Item

Selections/

Adjustments Range

CTRL

01 AC In Control

Auto Connect

≥Level 1

Auto

Connect

VDC Connect, Time Con-

nect, AC In – Disabled

≥Level 3

[1]

SOC Connect

≥Level 3 [1]

[6]

02 Charger Control

Multi-Stage, Start

Float, Start Bulk

≥Level 4

Multi-Stage

03 Gen Control

OFF, ON, AUTO

≥Level 1 [7]

OFF**

04 RTR Aux Relay

Force Open, Force

Closed, Auto VDC,

Auto VDC (BTS Comp),

Auto Fault, Auto SOC

≥Level 1

Force Open

METER

01 DC Meters

01A DC Volts to Inv

Read Only display

≥Level 1

Read Only

01B Inv/Chg DC Amps

02 AC Meters

02A AC Output Volts

Read Only display

≥Level 4 [3]

Read Only

02B AC Output Hz

≥Level 4

02C System AC Amps

≥Level 4 [4]

02D Inv/Chg Sys Amps

≥Level 4 [4]

02E AC Load Amps

≥Level 4 [4]

02F AC Input Amps

≥Level 4 [4]

02G Inv/Chg AC Amps

≥Level 4 [4]

02H Input Volts AC1

MSH Models

02I Input Volts AC2

MSH-RE

03 Timers

03A Charge Time

Read Only display

≥Level 1

Read Only

03B Days Since

04 AGS
Meters

04A AGS Status

Read Only display

≥Level 1

Read Only

04B DC Volts to AGS
04C Gen Run Time