Magnum Energy ME-RTR Router User Manual

Page 30

Advertising
background image

©

2014 Magnum Energy, Inc.

Page 22

Setup

Port-specifi c Inverter METER Menus
The following METER menus are available for each port-connected inverter. Information is for the

specifi c selected inverter (versus ALL-Port meters that are system meter information).
METER: 01 DC Meters
• 01A DC Volts to Inverter:
See information for 01A DC Volts to INV menu in previous section.
• 01B Inv/Chg DC Amps (In/Out of Battery): See information for 01B Inv/Chg DC Amps

menu in previous section.

METER: 02 AC Meters
• 02A

AC

Output: See information for 02A AC Output Volts and 02B AC Output Hz menus in

previous section.

• 02B AC Amps: See information for 02C System AC Amps menu in previous section.
• 02C Inv/Chg Amps (In/Out of Battery): See information for 02D Inv/Chg Sys Amps (In/

Out of Battery) menu in previous section.

• 02D AC Input Volts:

See information for 02H Input Volts AC1 menu in previous section.

Note: For a MSH-RE model inverters only, this menu also displays input volts for the AC2

source as well (02I Input Volts AC2). Refer to menu maps in Figure 4-2.

METER: 03 Timers
• 03A Charge Time:
See information for 03A Charge Time menu in previous section.

03B Days Since: See information for 03B Days Since menu in previous section.

Figure 3-10, Accessing Port-specifi c METER Menus

Press &

hold 3

secs

METER

Press to

view meters

Inverting

25.6VDC 20ADC
ALL System Home

To access

System Home screen:

Press the PORT

button until the

device’s Port

screen displays

PORT

01 DC Meters
02 AC Meters
03 Timers
P1 Select INV METER

MS4024PAE Master

Inverting

25.6VDC 20ADC
P1 INV Home

METER

Figure 3-9, ALL Ports vs Port-specifi c METER Menus

02C System AC Amps:
AC Load = 20 AAC
AC Input = 30 AAC
ALL Read AC METER

02B AC Amps:
AC Load = 20 AAC
AC Input = 30 AAC
P1 Read AC METER

All Ports

Inverter Single Port

Identifies Port#

Note that menu

prefix & title

may differ

3.3.3.1

Additional METER Menus for Port-connected Inverters

The METER button also provides meter displays for each active port-connected inverter (or

accessory) in your system. These displays are similar to those listed in Section 3.3.3, but the

displayed information is specifi c to the particular inverter and/or model (Figures 3-9 & 3-10 below).