Appendix B – Compatibility Matrix

Page 118

Button

FEATURES/SETTINGS

Model/

Level

Required

Default

Setting

Main Menu

Menu

Heading/Item

Selections/

Adjustments Range

METER

04 AGS
Meters

(cont.)

04D AGS Temp

Read Only display

≥Level 1

Read Only

04E Since Run Days
04F Since 100% Days
04G Gen Hour Meter

05 BMK
Meters

05A BMK SOC

Read Only display

≥Level 1

[6]

Read Only

05B DC Volts-BMK
05C DC Amps-BMK
05D Amp Hours In/Out
05E Resettable AHrs
05F Total kAHrs Out
05G Minimum VDC
05H Maximum VDC
05I Days Since 100%

SETUP

01 System

Setup

01A System Clock

Time = 12:00A-11:59P

≥Level 1

12:00A**

01B Screen Setup

Contrast = 0-100%

100%**

Brightness = 0-100%

50% **

01C Power Save

PowerSave= OFF, 1-60 min

15 Min

Port LEDs = Auto, OFF

Auto

01D Temp Display

Fahrenheit, Celsius

Fahrenheit

01E Viewing Ports

Auto Scroll = OFF, 1-60 sec

OFF

01F RTR Aux Relay

Open Volts = 8.0-17.0*

≥Level 1

10.0V

Close Volts = 8.0-17.0*

14.0V

Open Delay = 0-127 secs,

1-127 mins

10 secs

Close Delay = 0-127 secs,

1-127 mins

10 secs

01G Aux Relay SOC

Open = 20-100%

≥Level 4

[6]

50%

Close = 20-100%

100%

02 Invert

Setup

02A Search Watts

OFF, 5-50 Watts

≥Level 1

5 Watts

02B LBCO Setting

9.0-12.2* VDC

≥Level 2

10.0 VDC

02C AC In – Time

Connect=12:00A-11:45P

≥Level 3

[1]

6:00A

6:00P

Disconnect=12:00A-11:45P

02D AC In – Volts DC

Connect = 9.0-15.9*

≥Level 3

[1]

11.0V

Disconnect = 9.1-16.0*

14.1V

02E AC – In SOC

Connect = 20-99%

≥Level 3

[6]

80%

Disconnect = 21-100%

100%

02F Inv Always PowerUp NO, YES

≥Level 1

NO

02G Inverter Threshold

to Start Parallel

OFF, 30%-90%

MS-PAE,

MS-PE

60%