Using a BMK: Troubleshooting

8.3.2

Resolving BMK Faults using the Router

For the three BMK faults that follow, refer to its respective remedy.
• Factory Fault (FacFault) – The BMK has lost its factory-set internal calibration reference.

Remedy: Reset the BMK by removing all power from the BMK. After resetting the

BMK, if the Factory Fault remains or returns, the BMK will require repair at the Magnum

Energy factory service facility.

• Power-up

Fault (PwrFault) – The BMK’s power-up sequence failed.

Remedy: 1) Ensure the current sense wires are connected into pins 1 (blue wire) and

2 (orange wire), and the voltage wires are connected to pins 3 (black/negative) and 4

(red/positive). 2) Unplug the 4-port terminal block from the Sense Module, and then

check for the correct DC voltage on pins 3 (–) and 4 (+). The voltage must be between

7 to 70 volts DC depending on the nominal voltage of the inverter.

• Unknown

Fault ## (Fault##) – This fault message displays when the inverter/charger has

sent a fault code that is not recognized by the router.

Remedy: Call the Technical Support department at Magnum Energy (425-353-8833)

for assistance in determining and understanding the actual fault status

.

8.3 ME-BMK Troubleshooting (with the ME-RTR)

This section assists you in using the router to identify and resolve any faults or abnormal operational

conditions within your BMK system.

8.3.1

BMK Fault Message Screens for a Magnum Router

When an BMK fault is detected, the RTR’s FAULT LED (red) comes on and the fault status is displayed

on the LCD screen. Figure 8-7 is an example of how fault messages appear on the ME-RTR. Use

the RTR’s LCD screen and the information in this section to identify and correct the issue.
The FAULT LED lights solid red if the RTR’s display is on the port/device with the active fault, but

blinks if a different port/device has the active fault. Navigate to the port/device with the active

fault—the FAULT LED turns solid red when you are on the correct port/device.

Blinking (red)

FAULT LED

BMK Home Screen

FAULT

PWR

CHG

INV

Battery Monitor
Power-up Fault -.6AH
12.6VDC -0.0ADC
P2A BMK Home

Port Screen

Device Menu

Heading

DC Volts

Device

Status

Device

DC Amps

Solid (red)

FAULT LED

System Home Screen

System Status

FAULT

PWR

CHG

INV

Off

Power-up Fault -.6AH
12.6VDC -0.0ADC

ALL System Home

DC Volts

Device Menu

Heading

Accessory Status

DC Amps

AmpHrs I/O

AmpHrs I/O

Port Screen

Figure 8-7, ME-BMK Fault Message – Router Screens