• Internal Charger (Int Chgr) – This fault message displays when the FET bridge shuts down

because the charger circuit is trying to provide maximum current, but is not detecting any current

or voltage rise to the battery bank.

Figure 5-49, Internal Charger Fault

FAULT

PWR

CHG

INV

Internal Charger

Settings/Info...

Internal Charger appears on the LCD and the FAULT

(red) LED is on. The PWR (green), CHG (green), and

INV (green) LEDs are off.

Internal NTC appears on the LCD and the FAULT (red)

LED is on. The PWR (green), CHG (green), and INV

(green) LEDs are off.

FAULT

PWR

CHG

INV

Internal NTC

Settings/Info...

Figure 5-50, Internal NTC Fault

• Internal NTC (Int NTC) – This fault displays when the internal NTC (Negative Temperature

Coeffi cient) sensor suddenly senses a very large but unexpected temperature change.

Internal Relay appears on the LCD and the FAULT

(red) LED is on. The PWR (green), CHG (green), and

INV (green) LEDs are off.

FAULT

PWR

CHG

INV

Internal Relay

Settings/Info...

• Internal

Relay

(IntRelay) – This fault displays when the internal AC transfer relay is not

closed while charging.

Figure 5-51, Internal Relay Fault

• Internal Bridge (Int Brdg) – This fault message displays when the FET bridge shuts down

after the inverter has been inverting—the inverter output circuit can no longer detect any AC

output voltage or current.

Internal Bridge appears on the LCD and the FAULT

(red) LED is on. The PWR (green), CHG (green), and

INV (green) LEDs are off.

FAULT

PWR

CHG

INV

Internal Bridge

Settings/Info...

5.3.4.3

Internal Fault Messages

The inverter continually monitors several internal components. If a condition inside the inverter

occurs that does not allow proper operation, the inverter shuts down to protect itself. To clear

these “internal” faults, the inverter will require an inverter reset.

Remedy: Perform an inverter reset (see Section 6.2). After resetting the inverter,

press the ON/OFF INVERTER button to turn the inverter on and verify the fault has

cleared. If the internal fault remains, the inverter will require repair at a Magnum

Energy Authorized Service Center.

Figure 5-48, Internal Bridge Fault