Admin general statistics tab – Cobalt Co9992-4ENC-4K-HEVC Software-Defined Broadcast Encoder User Manual

Page 103

Advertising
background image

103

SNMP Traps:

This allows SNMP traps to be enabled or disabled

5

. You must click the

Reboot

button for the changes to take effect (image shown below).

Enable Parameter Blast:

This feature that speeds up DashBoard startup over high-

latency links (i.e., when the computer running DashBoard has a WAN connection to the
encoder or the frame housing the encoder). This feature requires DashBoard version
8.2 or later.

MIB File Download:

The 9992-ENC provides an up-to-date copy of its MIBs. If you

click on the

Save

button, a zip file with the relevant MIBs will be downloaded to your

computer. This zip file contains the card MIBs, as well as the Ross Video and
openGear MIBs required to compile the card MIBs.

Admin General Statistics Tab

The Admin General Statistics Tab is shown below. It shows the current configuration for the

Card Name, SNMP Traps

and

Enable Parameter Blast

controls.

This tab also includes one additional item,

Temperature Alarm,

which shows the current state

of the 9992-ENC thermal protection system. The possible values are:

None

: There is no temperature alarm and the 9992-ENC is operating normally.

Chassis Door Open:

The 9992-ENC has detected that the chassis door is open. The

ventilation fans are built into the chassis door; opening the door disengages the fans and
cuts the airflow. While the 9992-ENC can operate for short periods of time without this
airflow, such operation is not guaranteed over long periods of time (more than a few
minutes). The 9992-ENC will remain in yellow alarm for as long as the chassis door is
open. Depending on the chassis loading and ambient temperature, operating with the
door open for more than a few minutes can cause the 9992-ENC to overheat and shut
down.

FPGA Temperature Warning:

The 9992-ENC has detected that its internal

temperature has exceeded 70

o

C. The exact value can be found in the Product Statistics

Tab. While the 9992-ENC can operate indefinitely in this condition without any damage,
it is recommended that the situation be corrected as the thermal operation margin is
reduced.

FPGA Temperature Critical:

The 9992-ENC has detected that its internal

temperature has exceeded 80

o

C. The exact value can be found in the Product Statistics

Tab. While the 9992-ENC can operate indefinitely in this condition without any damage,
the situation

MUST

be corrected immediately. If the internal temperature reaches 85

o

C,

the 9992-ENC will

shut down

without any further notice to protect itself from damage.

5

SNMP is an optional feature in the openGear™ frame controller. The 9992-ENC SNMP functions are only

available if SNMP is licensed in the frame controller.

Advertising