Cobalt Co9992-4ENC-4K-HEVC Software-Defined Broadcast Encoder User Manual

Page 83

Advertising
background image

83



The configuration screen can be divided into two parts:

ASI Output Parameters

Input Selection Connection Parameters


The Connection Parameters are common to all outputs, and are described in the Connections Tab
section, later in this document. The ASI Output Parameters are:

Port Name:

All 9992-ENC encoders and outputs can be assigned a user-defined

Port

Name

. This name is used to identify the port later when making connections. Use any

descriptive name suitable for your application, or accept the default.

Packet Size:

Select between 188 and 204 bytes.

ASI Rate:

The following two modes are available:

o

Manual:

In this mode, the ASI output bit rate is set to the value entered in the

Bit

Rate

field. The ASI output will maintain this rate at all times, as follows:

If there is no connection to the ASI port, or if the input connected to the
ASI port is not active, the ASI port will transmit NULL packets.

ASI Output
Parameters

Input Selection
Connection
Parameters

Advertising