Cobalt Co9992-4ENC-4K-HEVC Software-Defined Broadcast Encoder User Manual

Page 40

Advertising
background image

40

Name:

All 9992-ENC encoders can be assigned a user-defined name. This name is used

to identify the encoder later when making connections. Use any descriptive name
suitable for your application, or accept the default.

Encoder State:

This control allows you to start/stop an encoder. This control needs to be

set to

Running

for normal operation.

Resolution:

This control only appears if the encoder is in Single-Channel mode. Select

HD

for resolutions up to 1920×1080p, and

4K

for 3840×2160 resolutions.

Input Port:

This control is present if the encoder is in Multi-Channel mode, or if

Resolution

is set to

HD.

It selects the input port to drive this encoder instance. Note that

multiple encoder instances can run independently from the same port, if desired. The
encoder will automatically detect the signal and configure itself for the detected
resolution and frame rate.

o

4K Signal Source:

This control replaces the

Input Port

if the encNotoder is in

Single-Channel mode and

Resolution

is set to

4K.

The options are shown below. The

encoder can operate in Single-Link mode, where it will accept either a 6G-SDI or a
12G-SDI signal (which can be applied to either Video 1 or Video 2), or in Quad-Link
mode, where it will take four SDI signals and combine them into one 4K image.

Notes:

o

While the encoder will automatically detect the frame rate of the incoming signal, it
must match the selection above. For example, if Quad-Link is selected but a
Single-Link signal is present, the encoder will not start.

o

In Quad-Link mode, the signals must be connected in the correct order. The order is
not automatically detected.

Loss of Video Action:

This control only appears if the

Enable Framesync

box in the

Video Inputs Configuration Tab is checked. Regardless of the framesync setting, the
9992-ENC will not start without a video input signal. This control defines the encoder
behavior if it loses the video signal

after

it is started. The options are:

Advertising