SMPTE 2022 FEC Support

The 9992-ENC supports one FEC session per Ethernet port. A checkbox for

SMPTE 2022 FEC

will be displayed if the feature is available. Once this feature is enabled for one of the streams in
a given Ethernet port, the checkbox will no longer be displayed.
Once the

SMPTE 2022 FEC

box is checked, additional parameters become available for

configuration:

FEC Mode:

If you select

Column Only

, the 9992-ENC will send a single FEC flow,

corresponding to the column protection data, using a UDP port number corresponding to
the media UDP port number plus 2. If you select

Row and Column

, the 9992-ENCwill

send two FEC flows, the first corresponding to the column protection data, and the
second corresponding to the row protection data. The row protection data will be sent
using a UDP port number corresponding to the media UDP port number plus 4. Note that
not all receivers support Row and Column mode; such receivers will only use the FEC
Column data and discard the FEC Row data.

Columns:

Number of columns in the FEC matrix. This variable must be between 1 and

20 if

FEC Mode

is set to

Column Only

, and between 4 and 20 if it is set to

Row and

Column

.

Rows:

Number of rows in the FEC matrix. This variable must be between 4 and 20.

FEC Overhead:

This field is updated as configuration is entered, and contains the

overhead for the selected FEC configuration. Note that not all parameter changes cause
the overhead to change. The FEC overhead is the sum of a Column overhead and a Row
overhead (which is zero if

FEC Mode

is

Column Only

). The overhead is a function of

the settings, as follows:

o

Increasing

the number of columns

decreases

the Row overhead (if enabled) and

does not change

the Column overhead.

o

Increasing

the number of rows

does not change

the Row overhead and

decreases

the Column overhead.

o

Decreasing

the number of rows and columns has the opposite effect as the

previous items.


The following constraints apply to the FEC function:

The number of rows must be between 4 and 20.

The number of columns must be between 1 and 20 for Column Only mode, or between 4
and 20 in Row and Column mode.