The size of the FEC matrix (product of the number of rows and the number of columns)
must not exceed 100.


The user interface will not allow invalid configurations to be entered, and will automatically
make parameter adjustments as required. Examples:

If you select Row and Column, and the number of columns is less than 4, it will be
automatically adjusted to 4.

If your number of rows is 10, and you set the number of columns to 20, the number of
rows will be automatically reduced to 5.


The number of rows and columns should be selected based on some understanding of the packet
loss characteristics of the network between the 9992-ENC and the receivers. If you have no
statistics on packet loss, the recommended setting is 20 columns and 5 rows to maximize the
correction capabilities. Most receivers that support SMPTE 2022 FEC provide packet
loss/recovery statistics. After running for a while, if the network is found to be clean, consider
reducing the matrix to 10 rows and 10 columns, which will reduce the overhead.

Completing the Configuration

Once the configuration information is filled in, click on the

Apply

button to make it active. If

there are no errors, the stream will be created, and the configuration area disappears. If any
errors are detected, they will be displayed at the top of the

Apply

button.

The following configuration-related errors are flagged:

Error: UDP Port/Address conflict with Port X/Y

: you have configured two IP Output

streams with the same destination IP Address and UDP port, on the same Ethernet
interface. Please review your settings. Note that ports with FEC enabled will use either
two or three UDP ports (depending on the FEC settings) – these are checked as well.

Maximum number of streams exceeded on this port

: you will receive this message if

you attempt to create more than 4 IP outputs on a given Ethernet port.

Error: No SMPTE 2022 FEC License Available

: the SMPTE 2022 function requires

licensing. Please contact Cobalt Digital to obtain a license.

If the configuration is successful, the output stream will be added to the Active IP Outputs table.

Active IP Outputs Table

Once the output is created, it is added to the

Active IP Outputs

table, which has

Basic

and

Advanced

views. This table provides a summary of the configuration and status of the output

stream. An example of this table, in the Basic view, is depicted below.