Cobalt Co9992-4ENC-4K-HEVC Software-Defined Broadcast Encoder User Manual

Page 88

Advertising
background image

88

Connections section, later in this document.


The Basic View configuration parameters are as follows:

Enabled:

This allows the output stream to be enabled or disabled. If it is disabled, no

packet transmission takes place. This feature is provided for testing purposes (i.e.,
temporarily disable an output for fault-finding). Most users will leave the stream
enabled.

UDP Port:

selects the UDP transmit port. Valid values are between 1 and 65535. Note

that, in traditional IP networks, UDP ports between 1 and 1023 are reserved for
administrative uses. It is recommended to use UDP ports 1024 and higher. The
9992-ENC, however, will accept any legal value. Note that if the port is configured for
RTP, the UDP port must be an even number, and the 9992-ENC interface will enforce
this restriction – odd numbers will be automatically rounded up.

Destination Address:

selects the IP address to transmit to. Any unicast or multicast

address can be entered here, with the exception of the loopback range (127.0.0.0 to

IP Output