Cobalt Co9992-4ENC-4K-HEVC Software-Defined Broadcast Encoder User Manual

Page 21

Advertising
background image

21

Alarm on Link Loss:

If set to

Yes

, the card will raise an alarm if this Ethernet interface

loses link. The Card State indicator in Dashboard™ and the front Status LED will both
be red. If set to

No

, the card will still report loss of link in the Statistics page but no

alarm will be raised. It is recommended that the alarm for ports that are in use be turned
on; only turn it off if you do not plan to connect that port to a network.

IP Configuration:

Select

Static

or

DHCP

method for configuration. If

Static

is

selected, the following options are displayed:

o

IP Address:

Enter the desired IP address for this Ethernet port.

o

Subnet Mask:

Enter the desired subnet mask for this Ethernet port.

o

Default Gateway:

Enter the desired default gateway for this Ethernet port, or

0.0.0.0 if no gateway is available.

Interface speed:

Configures the speed of the interface. The 9992-ENC Ethernet

interfaces only support two modes: 100 Mb/s Full-Duplex and 1 Gb/s Full-Duplex

4

.

o

Auto-Negotiate:

The Ethernet port will auto-negotiate the speed.

o

100 Mb/s Full-Duplex:

Force the port to 100Mb/s Full-Duplex mode. Note that

the port will still perform auto-negotiation, but it will only advertise this mode.

o

1Gb/s Full-Duplex:

restrict the operation to 1Gb/s Full-Duplex mode. Note that

the port will still perform auto-negotiation, but it will only advertise this mode.

Notes:

o

If the 9992-ENC streaming Ethernet interfaces are connected, to a 10 Mb/s
switch, hub, or network feed, link will

not

be established and the port will not

recognize the connection.

o

If you select

100 Mb/s Full-Duplex

or

1 Gb/s Full-Duplex

and the

corresponding streaming Ethernet interface is connected to a switch, hub or
network feed that does not support the selected speed, link will

not

be established

and the port will not recognize the connection.

o

If the interface speed is set to

Auto-Negotiate

, the streaming Ethernet port will

allow link to be established in 100 Mb/s Half-Duplex mode. However, this will
be flagged as a warning.

Interface Settings:

If you make any changes to the IP Configuration, IP Address, Subnet

Mask and/or Default Encoder fields, the

Apply

and

Cancel

buttons become active. The

changes only take effect when you press the

Apply

button. Pressing the

Cancel

button

reverts the fields back to their original values.
Note that the 9992-ENC will check the consistency of the data entered and will reject
invalid combinations (i.e., combinations where the gateway is outside the interface
subnet).

Once the

Apply

button is pressed, a confirm message appears, click

Yes

to apply setting or

No

.

4

Support for 10 Mb/s and Half-Duplex modes are not offered, as these are unsuitable for MPEG transport over IP

applications. Moreover, any modern switch supports at least 100 Mb/s Full-Duplex.