P.2.4 error marking for cacheable data error, Error marking for cacheable data – FUJITSU Implementation Supplement Fujitsu SPARC64 V User Manual

Page 168

Advertising
background image

Release 1.0, 1 July 2002

F. Chapter P

Error Handling

157

P.2.3

Extent of Automatic Source Data Correction for
Correctable Error

Upon detection of the following correctable errors (

CE

), the CPU corrects the input

data and uses the corrected data; however, the source data with the

CE

is not

corrected automatically.

CE

in memory (DIMM)

CE

in

ASI_INTR_DATA_R

Upon detection of other correctable errors, the CPU automatically corrects the source
data containg the

CE

.

For correctable errors in

ASI_INTR_DATA

, no special action is required by

privileged software because the erroneous data will be overwritten when the next
interrupt is received. For

CE

in memory (DIMM), it is expected that privileged

software will correct the error in memory.

P.2.4

Error Marking for Cacheable Data Error

Error Marking for Cacheable Data

Error marking for cacheable data involves the following action:

Number of
errors
indicated at
trap

All FEs are
detected and
accumulated in

ASI_STCHG_

ERROR_INFO

All EEs are
detected and
accumulated in

ASI_STCHG_

ERROR_INFO

Single-ADE trap

All

I_UGE

s and

A_UGE

s

detected at trap.

Multiple-

ADE

trap

The multiple-

ADE

indication

+

UGE

s at first

ADE

trap.

IAE

One error

DAE

One error

All restrainable errors
detected and accumulated
in

ASI_AFSR

.

Error address
indication
register

None

None

I_UGE

,

A_UGE

: None

IAE

:

TPC

DAE

:

ASI_DFAR

ASI_AFAR_D1

ASI_AFAR_U2

TABLE P-2

Action Upon Detection of an Error (4 of 4)

Fatal Error (FE)

Error State Transition

Error (EE)

Urgent Error (UGE)

Restrainable Error (RE)

Advertising