Release 1.0, 1 July 2002

F. Chapter P

Error Handling

165

Ideal specification (not implemented)
The

EE_OTHER

bit is specified in

ASI_STCHG_ERROR_INFO

bit 14. When

hardware detects

error_state

transition errors other than those described

above, it sets

ASI_STCHG_ERROR_INFO.EE_OTHER

= 1.

P.4

Urgent Error

This section presents details about urgent errors: status monitoring, actions, and
end-methods.

P.4.1

URGENT ERROR STATUS (

ASI_UGESR

)

The ASI_UGESR

register contains the following information when an

async_data_error

(

ADE

) exception is generated.

Detected

I_UGE

s and

A_UGE

s, and related information

The type of second error to cause multiple

async_data_error

traps

TABLE P-11

describes the fields of the

ASI_UGESR

register. In the table, the prefixes in

the name field have the following meaning:

IUG_

Instruction Urgent error

IAG_

Autonomous

Urgent

error

IAUG_

The error detected as both

I_UGE

and

A_UGE

[1]

Register name:

ASI_URGENT_ERROR_STATUS

[2]

ASI:

4C

16

[3]

VA:

08

16

[4]

Error checking:

None

[5]

Format & function:

See

TABLE P-11

.

[6]

Initial value at reset:

Hard POR: All fields are set to 0.
Other resets: The values of all

ASI_UGESR

fields are

unchanged.

TABLE P-11

ASI_UGESR

Bit Description (1 of 4)

Bit

Name

RW Description

Each bit in

ASI_UGESR

<22:8> indicates the occurrence of its corresponding error in a single-

ADE

trap as follows:

0:

The error is not detected.

1:

The error is detected.

Each bit in

ASI_UGESR

<22:16> indicates an error in a CPU register. The error detection conditions for these

errors are defined in Handling of Internal Register Errors on page 181.

Advertising