P.8 handling of internal register errors, Handling of internal register errors 181, P.8.1 an – FUJITSU Implementation Supplement Fujitsu SPARC64 V User Manual

Page 192

Advertising
background image

Release 1.0, 1 July 2002

F. Chapter P

Error Handling

181

P.8

Handling of Internal Register Errors

This section describes error handling for the following:

Most registers

ASR registers

ASI registers

P.8.1

Register Error Handling (Excluding ASRs and ASI
Registers)

The terminology used in

TABLE P-18

is defined as follows:

TABLE P-18

shows error handling for most registers.

Column

Term

Meaning

Error Detect
Condition

InstAccess

The error is detected when the instruction accesses the register.

Correction

W

The error indication is removed when an instruction performs a
full write to the register

ADE

trap

The error is removed by a full write to the register in the

async_data_error

hardware trap sequence.

TABLE P-18

Register Error Handling (Excluding ASRs and ASI Registers)

Register Name

RW

Error
Protect

Error Detect Condition

Error Type

Correction

%r

n

RW

Parity

InstAccess

IUG_%R

W

%f

n

RW

Parity

InstAccess

IUG_%F

W

PC

Parity

Always

IUG_PSTATE

ADE

trap

nPC

Parity

Always

IUG_PSTATE

ADE

trap

PSTATE

RW

Parity

Always

IUG_PSTATE

ADE

trap

TBA

RW

Parity

PSTATE.RED

= 0

error_state

W (by

OBP

)

PIL

RW

Parity

PSTATE.IE

= 1

or InstAccess

IUG_PSTATE

W

CWP

,

CANSAVE

,

CANRESTORE

,

OTHERWIN

,

CLEANWIN

RW

Parity

Always

IUG_PSTATE

ADE

trap, W

TT

RW

None

TL

RW

Parity

PSTATE.RED

= 0

error_state

W (by

OBP

)