Panasonic MN101C77C User Manual

Page 246

Advertising
background image

Chapter 6 8-bit Timers

VI - 32

Synchronous Output

TM1BC counts up from x'00'. If any data is written to the port 6 output register (P6OUT), the data of

port 6 is output from the synchronous output pin in every time an interrupt request is generated by

the match of TM1BC and the set value of the TM1OC register.

Setup Procedure

Description

(7)

Set the synchronous output generation cycle

to the timer 1 compare register (TM1OC).

The setting value is set to 100-1=99(x'63'),

because 1 MHz is divided by 10 kHz.

At that time, the timer 1 binary counter

(TM1BC) is initialized to x'00'.

(8)

Set the TM1EN flag of the TM1MD register to

"1" to start timer 1.

(7)

Set the synchronous output event

generation cycle.

TM1OC (x'3F53')

= x'63'

(8)

Start the timer operation.

TM1MD (x'3F55')

bp3

:TM1EN

= 1

Advertising