4-2 setup example – Panasonic MN101C77C User Manual

Page 277

Advertising
background image

VII - 17

Chapter 7 16-bit Timer

16-bit Event Count

7-4-2

Setup Example

„

Event Count Setup Example (Timer 7)

If the falling edge of the TM7IO input pin signal is detected 5 times with using timer 7, an interrupt is
generated. An example setup procedure, with a description of each step is shown below.

(1) Set the TM7EN flag of the timer 7 mode register

1 (TM7MD1) to "0" to stop timer 7 counting.

(2) Set the P1DIR4 flag of the port 1 direction

control register (P1DIR) to "0" to set P14 pin to
input mode.
If it needs, pull-up resistor should be added.

(3) Set the TM7BCR flag of the timer 7 mode

register 2 (TM7MD2) to "1" to select the
compare match as a clear source of binary
counter.

(4) Select the TM7IO input as a clock source by the

TM7CK1-0 flag of the TM7MD1 register. Also,
select 1/1(no division) as a count clock source
by the TM7PS1-0 flag.

(5) Set the interrupt generation cycle to the timer 7

preset register 1 (TM7PR1). The set value
should be 4, because the counting is 5 times.
At that time, the same value is loaded to the
timer 7 compare register 1 (TM7OC1), and the
timer 7 binary counter (TM7BC) is initialized to
x'0000'.

Setup Procedure

(1) Stop the counter.

TM7MD1 (x'3F78')

bp4

: TM7EN

= 0

(2) Set the special function pin to input

mode.

P1DIR (x'3F31')

bp4

: P1DIR4

= 0

(3) Select the condition for timer clear.

TM7MD2 (x'3F79')

bp5

: TM7BCR = 1

(4) Select the count clock source.

TM7MD1 (x'3F78')

bp1-0

: TM7CK1-0 = 10

bp3-2

: TM7PS1-0 = 00

(5) Set the interrupt generation cycle.

TM7PR1 (x'3F75', x'3F74')=x'0004'

Description

[

Chapter 4 I/O Ports ]

Advertising