Panasonic MN101C77C User Manual

Page 423

Advertising
background image

Chapter 12 Serial Interface 3

Operation

XII - 37

Setup Procedure

Description

(5)

Set ACK bit.

SC3CTR (x'3FAA')

bp0 : SC3ACKO = x

bp1 : SC3ACKS = 1

(6)

Select the communication type.

SC3CTR (x'3FAA')

bp2 : SC3CMD = 1

<Transmission setup>

(7)

Select the transmission/reception

mode.

SC3CTR (x'3FAA')

bp3 : SC3REX = 0

(8)

Initialize the monitor flag.

SC3CTR (x'3FAA')

bp6 : SC3STC = 0

bp7 : IICBSY = 0

(9)

Set the SC3MD0 register.

Select the transfer bit count.

SC3MD0 (x'3FA8')

bp2-0 : SC3LNG2-0 = 111

(10) Select the start condition.

SC3MD0 (x'3FA8')

bp3 : SC3STE = 1

(11) Select the first bit to be transferred.

SC3MD0 (x'3FA8')

bp4 : SC3DIR = 0

(12) Select the IIC communication edge.

SC3MD0 (x'3FA8')

bp6 : SC3CE1 = 1

(5)

Set the SC3ACKS flag of the serial 3 control

register (SC3CTR) to "1" to select "receive ACK

bit". At transmission, ACK bit is received, so that

the SC3ACKS flag does not need to set the ACK

bit level.

(6)

Set the SC3CMD flag of the serial 3 control

register (SC3CTR) to "1" to select IIC.

(7)

Set the SC3REX flag of the serial 3 control

register (SC3CTR) to "0" to select the

transmission mode.

(8)

Set the SC3STC flag and the IICBSY flag of the

serial 3 control register (SC3CTR) to "0, 0" to

initialize the start condition detection flag and the

BUSY flag.

(9)

Set the SC3LNG2-0 flag of the serial 3 mode

register (SC3MD0) to "111" to set the transfer

bit count to 9 bits.

(10) Set the SC3STE flag of the SC3MD0 register to

"1" to enable start condition.

(11) Set the SC3DIR flag of the SC3MD0 register to "0"

to set MSB as the first bit to be transferred.

(12) At IIC communication, set the SC3CE1 flag of the

SC3MD0 register to "1", always.