Xvii - 7 – Panasonic MN101C77C User Manual

Page 507

Advertising
background image

XVII - 7

Chapter 17 Appendices

Special Function Registers List

P6 Synchronous Output

Event Selection

Bit Symbol /Initial Value /Description

Port 6 Synchronous Output Selection

Port 8 Input Data

Port 2 Input Data

Port 8 Transistor Selection

Port 6 Input Data

Port 7 Input Data

Port 0 I/O Direction Control

X'3F1D'

X'3F1E'

X'3F20'

X'3F21'

X'3F22'

X'3F25'

X'3F26'

X'3F27'

X'3F28'

X'3F2A'

X'3F2E'

Address

X'3F2F'

X'3F30'

X'3F31'

X'3F2D'

P8LED

P6SYO

P5IN

P6IN

P7IN

P8IN

PAIN

FLOAT

Register

P0IN

P1IN

P2IN

P1OMD

P0DIR

P1DIR

OSCMD

Bit 7

P6SYO7

P8IN7

-

-

-

-

P2IN7

P8LED7

-

P6IN7

P7IN7

-

-

-

-

Bit 6

P6SYO6

P8IN6

PAIN6

PARDWN

P0IN6

-

-

P8LED6

-

P6IN6

P7IN6

PA Pull-up/down

Selection

P1OMD6

P0DIR6

-

-

Bit 5

P6SYO5

P8IN5

PAIN5

-

P0IN5

-

-

P8LED5

-

P6IN5

P7IN5

P1OMD5

P0DIR5

-

-

Bit 4

P6SYO4

P8IN4

PAIN4

P7RDWN

P0IN4

P1IN4

P2IN4

P8LED4

P5IN4

P6IN4

P7IN4

P1OMD4

P0DIR4

P1DIR4

-

Bit 3

P6SYO3

P8IN3

PAIN3

Port A Input Data

P0IN3

Port 0 Input Data

P1IN3

P2IN3

P8LED3

P5IN3

P6IN3

P7IN3

P1OMD3

P0DIR3

P1DIR3

-

Bit 2

P6SYO2

P8IN2

PAIN2

-

P0IN2

P1IN2

Port 1 Input Data

P2IN2

P8LED2

P5IN2

Port 5 Input Data

P6IN2

P7IN2

P1OMD2

P0DIR2

P1DIR2

Port 1 I/O Direction Control

-

Bit 1

P6SYO1

P8IN1

PAIN1

SYOEVS1

P0IN1

P1IN1

P2IN1

P8LEDT1

P5IN1

P6IN1

P7IN1

P1OMD1

P0DIR1

P1DIR1

SOSC2DS

Low Frequency

Divided by 2

Bit 0

P6SYO0

P8IN0

PAIN0

SYOEVS0

P0IN0

P1IN0

P2IN0

P8LED0

P5IN0

P6IN0

P7IN0

P1OMD0

P0DIR0

P1DIR0

Reserved

Set always

to "0"

IV - 39

IV - 28

IV - 38

IV - 42

IV - 32, 43

Page

IV - 7

IV - 13

IV - 18

IV - 22

IV - 27

IV - 31

IV - 14

IV - 13

IV - 7

II - 25

X'3F2B'

KEYCNT

-

-

-

-

-

-

-

LOCKEN

Register Data

Protection

Function

II - 42

Port A Output Data

X'3F1A'

PAOUT

PAOUT6

PAOUT5

P8OUT4

P8OUT3

P8OUT2

P8OUT1

P8OUT0

IV - 42

-

-

P77 Output mode

Selection

X'3F32'

P2DIR

-

-

-

P2DIR4

P2DIR3

P2DIR2

Port 2 I/O Direction Control

P2DIR1

P2DIR0

IV - 18

X'3F35'

P5DIR

-

-

-

P5DIR4

P5DIR2

Port 5 I/O Direction Control

P5DIR1

P5DIR0

IV - 22

P5DIR3

P76 Output mode

Selection

P14 Output mode

Selection

P13 Output mode

Selection

P12 Output mode

Selection

P11 Output mode

Selection

P10 Output mode

Selection

P7 Pull-up/down

Selection

Advertising
This manual is related to the following products: