2-3 timer mode registers – Panasonic MN101C77C User Manual

Page 268

Advertising
background image

Chapter 7 16-bit Timer

VII - 8

Control Registers

7-2-3

Timer Mode Registers

This is a readable / writable register that controls timer 7.

„

Timer 7 Mode Register 1 (TM7MD1)

Figure 7-2-13 Timer 7 Mode Register 1 (TM7MD1 : x'03F78', R/W)

TM7CK1

0

TM7CK0

0

1

0

1

1

0

1

fs

TM7IO input

Synchronous TM7IO input

Clock source selection

fosc

0

1

2

4

5

6

7

3

( At reset : 0 0 1 0 0 0 0 0 )

TM7MD1

TM7CK0

TM7CK1

TM7PS0

TM7PS1

TM7EN

TM7CL

RESERVED

0

1

Disable the count

Timer 7 count control

Enable the count

TM7EN

0

1

Operate timer output

Timer output reset control

Disable timer output (reset)

TM7CL

TM7PS1

TM7PS0

0

1

0

1

1/2 of clock

Count clock selection

1/1 of clock

1/16 of clock

1/4 of clock

Set always "0".