Chapter 2 CPU Basics

II - 36

ROM Correction

The first correct program instruction code

0000
0001
0002
0003
0004
0005
0006
0007
0008
0009

000A
000B
000C
000D
000E
000F

0010
0011
0012
0013
0014
0015
0016
0017
0018
0019

03
19
09
01

B4

06

FD

08
01

BC

06

0A

00
85
93

C2

91
F0

FF
0A

14
85
93
02
90
00

Program management version.

Set value to the ROM correction address 0 setting register

(RC0AP)

Set value to the ROM correction address 1 setting register

(RC1AP)

The head address of the development first correct program

For half-byte instruction adjustment

(no need to the real ROM)

Address

Data

External EEPROM

06B4
06B5
06B6
06B7
06B8
06B9

06BA
06BB
06BC
06BD
06BE
06BF
06C0
06C1
06C2

0A

00
85
93

C2

91
F0

FF
0A

14
85
93
02
90
00

Address

Data

Internal RAM

develop

The second correct program instruction code

The head address of the development second correct program

10916
10919

1091B
1091C
1091E

D900A0
A005
58
8940
B4

Address

Data

The first program to be corrected (internal ROM)

cbne

0, d1, 1091E

mov

50, d0

mov

d0, (a0)

bra

10920

sub

d0, d0

The head address of the correction

(the set value of RC0AP)

The address for recover

006B4
006B6
006B7

A000
58
392C190

Address

Data

The first correct program (internal RAM)

mov

0, d0

mov

d0, (a0)

bra

1091C

The head address of the correction program

(the set value of RC0V)

The addres for recover

„

ROM Correction Setup Example

The setup procedure with ROM correction to correct 2 parts of the program is shown below.

For the step to execute the ROM correction, refer to figure 2-7-12. Initial Routine for ROM correction on

the previous page.

(STEP 1)

Develop the correct program of the external EEPROM to RAM area.

(STEP 2)

Set the ROM correction address setting register and the RC vector table.

[Setup for the first correction]

Set the head address of the program to be

corrected at first to the ROM correction address 0

setting register (RC0AP).

RC0APL = x'19'

RC0APM = x'09'

RC0APH = x'01'

Set the internal RAM address x'06B4' that stored the

first correct program to the RC vector table address

(RC0V(L), RC0V(H).

RC0V(L) = x'B4'

RC0V(H) = x'06'

Advertising